- Can achieve Category 2, PL c, when used with proper safety controls
- The “fail-to-safe” safety function is ensured as long as the poppet is able to go back into the start position
- The Cat 2 version (MDC2) of the MDC Series is equipped with a solid state pressure sensor.
- Monitoring the sensor on each actuation and de-actuation of the MDC2 Series valve provides a diagnostic coverage between 60% < 90%
- Poppet Design that is dirt tolerant, wear compensating for quick response and high flow capacity
- PTFE backup piston rings enhances valve endurance enabling operation with or without in-line lubrication
- On energization, the Soft-Start (EEZ-ON®) allows outlet pressure to increase at a slower rate until it reaches approximately 50% of inlet pressure, at which point the valve will then open fully to finish filling the system at full rate
- Threaded or modular port connection allows connection to Air Entry System (Lockout Valve, FRLs)
- Threaded exhaust port for canister silencer or remote exhaust
- SISTEMA Library available for download
Product Information
Series | MDC |
Valve Function | 3/2 Single Solenoid |
Construction | Poppet |
Actuation | Electrical |
Soft Start | Not Included |
Lockout | Not Included |
Monitoring | External |
Feedback | Pressure Switch (PNP) |
Reset | Not Included |
Basic Size | 1" |
Inlet Size | 1" |
Outlet Size | 1" |
Exhaust Size | 1-1/2" |
Exhaust Type | Threaded Female Port |
Thread Type | NPT |
Thread Type | G |
Feedback Rating | 5 amps at 250 volts AC, or 5 amps at 30 volts DC |
Voltage | 24 VDC |
Solenoid Connection | M12 |
Feedback Connection | M12 |
Operating Pressure (bar) | 2.5 to 10.3 |
Pressure Gauge | Analog Gauge |
Weight (kg) | 4.24 |
Mounting | Inline |
Ambient Temperature Range (Celcius) | 4 to 50 |
Media Temperature Range (Celcius) | 4 to 80 |
Flow Media | Compressed Air |
Valve Body Material | Aluminum |
Poppet/Spool Material | Acetal and Stainless Steel |
Seal Material | Buna-N |
Safety Category | Category 2 |
PL Rating | PL c |
Safety Integrity Level | SIL 1 |
DGUV Certification | Pending |
CE Certification | Yes |
EAC Declaration | Yes |
CSA/UL Certification | Yes |